All Calculators

110 professional MEP tools - calculators, BOQ estimators, cost estimates, branded PDF reports.

🔥 In-Demand
📊 Project Dashboard
click to expand
99
🧮 Calculators
15
📚 Design Guides
28
📐 Formulas
-
No calculator opened yet
Open any calculator to track it here
Open →
0
Calcs Today
0
Favourites
99
Total Calculators
⚡ Quick Access - BOQ Estimators
💨 HVAC BOQ
⚡ Electrical BOQ
💧 Plumbing BOQ
🔥 Fire Fighting BOQ
🏗️ MEP Cost
Select minimum cable size satisfying current capacity and 3% VD limit. IS 732 / BS 7671.
IS 732BS 7671Cable
Calculate
Check cable voltage drop vs IS 732 3% limit for LV branch circuits.
IS 732LVCable
Calculate
Minimum wire cross-section from VD constraint. Returns mm² and AWG equivalent.
WireAWGNEC
Calculate
Room cooling load for Indian climates using simplified ASHRAE CLTD method. Outputs TR.
ASHRAENBCCooling
Calculate
Size round or rectangular ducts by equal friction method. ASHRAE/SMACNA compliant.
ASHRAESMACNADuct
Calculate
Total Dynamic Head and pump power by Darcy-Weisbach for water supply and HVAC.
TDHDarcyPump
Calculate
Domestic water pipe sizing by velocity method with Hunter fixture unit approach. IS 1172.
IS 1172CPWDHunter
Calculate
Size LPG/PNG/Natural Gas pipes using Weymouth formula for low-pressure systems.
WeymouthIS 6044LPG
Calculate
Duty point for sprinkler and hydrant fire pump systems. NFPA 13 / NBC India.
NFPA 13NBCSprinkler
Calculate
Full sprinkler coverage: head spacing, head count, branch/main pipe sizes. NFPA 13/IS 15105.
NFPA 13IS 15105Sprinkler
Calculate
Multi-load genset sizing with DOL/Star-Delta/VFD motor starting kVA. IS 10000.
IS 10000GensetkVA
Calculate
Average lux level by lumen method. Pass/Fail vs IS 3646 / NBC India room standards.
IS 3646NBCLux
Calculate
More Calculators
Medium-pressure gas pipe sizing using Spitzglass formula. IGEM UP/2 / IS 6044.
SpitzglassMedium PIGEM
Calculate
Size compressed air pipework for industrial systems. Includes compressor duty estimate.
Comp AirBS EN ISOCAGI
Calculate
Detailed genset sizing with temperature, altitude and harmonic derating. IS 10000/ISO 8528.
IS 10000ISO 8528Derating
Calculate
Size underground SWA/XLPE cables with ground temperature and grouping derating. IS 7098/BS 5467.
SWAXLPEIS 7098
Calculate
3-phase and 1-phase fault current at an LV switchboard. IEC 60909.
IEC 60909FaultIsc
Calculate
Number of sprinklers, spacing, water demand and min pressure by area and hazard. NFPA 13/IS 15105.
NFPA 13IS 15105Water Demand
Calculate
Pipe sizing by Hazen-Williams formula for water/HW/CW systems. IS 1239/NBC India.
Hazen-WilliamsIS 1239NBC
Calculate
Pressure drop in ductwork including bends and fittings. Altschul-Tsal equation. ASHRAE/SMACNA.
AltschulASHRAESMACNA
Calculate
Size gas distribution pipes from appliance kW loads. Converts heat demand to flow. IS 6044/IGC.
IS 6044IGCAppliance
Calculate
Compressed air ring main sizing with multiple outlets, pressure drop and receiver sizing. ISO 8573.
ISO 8573Comp AirRing Main
Calculate
Multi-load transformer sizing with diversity/demand factors. IS 2026 standard kVA selection.
IS 2026TransformerkVA
Calculate
Generator sizing with separate critical and non-critical load lists. Fuel tank for 8hr/24hr runs. IS 10000.
IS 10000Critical LoadFuel Tank
Calculate
Building-level chiller capacity for offices, hospitals, hotels, malls. ASHRAE/NBC India.
ASHRAENBCChiller
Calculate
Building water supply: WSFU, peak flow, riser/branch pipe sizes and tank capacity. IS 2065.
IS 2065NBCWSFU
Calculate
Full SWA cable sizing for LV (415V), HT (11kV, 33kV) feeders with short circuit rating check.
IS 7098HV/LVShort Circuit
Calculate
Agent quantity, cylinder count and vent sizing for clean-agent suppression rooms. NFPA 2001/ISO 14520.
NFPA 2001FM200ISO 14520
Calculate
Complete hydrant system: flow, pressure, pipe sizing, pump duty, jockey pump and storage tank. NBC/IS 3844.
NBC IndiaIS 3844TAC
Calculate
Full hydraulic balance for sprinkler pipe network. Hazen-Williams C=120. NFPA 13/IS 15105.
NFPA 13Hazen-WilliamsHydraulic
Calculate
Required exhaust airflow, fan count, makeup air and shaft size for smoke control systems.
NBC IndiaNFPA 92BS 7346
Calculate
Fresh air, ACH and exhaust quantity per occupancy and room type. ASHRAE 62.1 / NBC India.
ASHRAE 62.1NBCACH
Calculate
CHW flow rate, pipe size, pressure drop, insulation thickness and pump head. ASHRAE/CIBSE Guide C.
ASHRAECIBSEChilled Water
Calculate
Capacity, water flows, evaporation loss, blowdown and makeup water requirement. CTI/ASHRAE.
CTIASHRAECooling Tower
Calculate
Sump and overhead tank sizing, dimensions, pump capacity and refill time. NBC India/IS 1172.
NBC IndiaIS 1172Tank
Calculate
Stack and branch sizing from drainage fixture units using Manning's equation. IS 5329/NBC India.
IS 5329ManningDFU
Calculate
Pump head, motor power, stages, pressure vessel sizing and duty point. IS 1520/NBC India.
IS 1520Booster PumpMultistage
Calculate
Comprehensive cable sizing per IS 732/IS 1554/IS 7098 with full derating, designation and SC check.
IS 732IS 1554IS 7098
Calculate
Conduit size from cable space factors, bend correction and IS 9537 standard sizes.
IS 9537BS 6053Conduit
Calculate
Required sanitary fixtures by occupancy type per NBC India 2016 Table 1 & 2.
NBC 2016IS 1172Fixtures
Calculate
Earth electrode resistance, combined resistance and conductor sizing per IS 3043 / IEEE 80.
IS 3043IEEE 80Earthing
Calculate
3ϕ, 1ϕ, L-L fault currents, fault MVA, switchgear rating and busbar requirements. IS 13234/IEC 60909.
IS 13234IEC 60909Fault MVA
Calculate
📋
HVAC
HVAC BOQ Estimator
Bill of Quantities for HVAC systems with INR rates. CPWD DSR 2023 / India market 2024-25.
BOQHVACCPWD DSR
📋
ELECTRICAL
Electrical BOQ Estimator
Bill of Quantities for electrical systems with INR rates. CPWD DSR 2023 / India market 2024-25.
BOQElectricalCPWD DSR
📋
PLUMBING
Plumbing BOQ Estimator
Bill of Quantities for plumbing & drainage systems. CPWD DSR 2023 / India market 2024-25.
BOQPlumbingCPWD DSR
📋
FIRE
Fire Fighting BOQ Estimator
Bill of Quantities for fire protection systems. CPWD DSR 2023 / India market 2024-25.
BOQFireCPWD DSR
🏗️
MECH
MEP Master Cost Estimator
Combined MEP project cost estimate with CPWD DSR benchmarks and city factor. Printable report.
CPWD DSRBOQCost Estimate
Calculate capacitor bank size (kVAr) to correct power factor to target. IS 732 / IEEE 1459.
PFCapacitorkVArIS 732
Calculate
Size a UPS / online inverter from connected load, PF and backup time. IS 16242 / IEC 62040.
UPSInverterBackupIS 16242
Calculate
Size rooftop solar PV system - panels, inverter, generation estimate. IS 16221 / MNRE.
SolarPVRooftopMNREIS 16221
Calculate
DOL / Star-Delta / VFD starter and cable selection for 3-phase motors. IS 8544 / IEC 60947.
MotorDOLStar-DeltaVFDIS 8544
Calculate
Estimate EV charging electrical load, cable and circuit breaker sizing. IS 17017 / IEC 61851.
EVElectric VehicleChargingIS 17017
Calculate
Check LPD (W/m²) vs ECBC / NBC limits for energy compliance.
LPDECBCLightingEnergyNBC
Calculate
Size Air Handling Unit - airflow, coil, fan kW and duct connection. ASHRAE 62.1 / NBC Part 8.
AHUAir Handling UnitASHRAENBC
Calculate
Minimum insulation thickness for pipes and ducts to prevent condensation and heat gain. IS 14164 / ASHRAE 90.1.
InsulationPipeDuctCondensationIS 14164
Calculate
Size Variable Air Volume (VAV) box from zone cooling load. ASHRAE / SMACNA.
VAVVariable Air VolumeASHRAESMACNA
Calculate
Calculate wet bulb, dew point, humidity ratio, enthalpy from DB and RH. ASHRAE Fundamentals.
PsychrometricWet BulbEnthalpyHumidityASHRAE
Calculate
Calculate fan BHP / kW from airflow and static pressure. AMCA / ASHRAE 90.1.
FanBHPStatic PressureAMCAASHRAE
Calculate
Size liquid and suction refrigerant pipes for VRF and split AC systems. ASHRAE / Manufacturer guidelines.
VRFRefrigerantPipeSplit ACASHRAE
Calculate
Size rainwater collection tank and recharge pit. NBC Part 9 / IS 15797.
RainwaterHarvestingNBCIS 15797
Calculate
Size kitchen grease trap / interceptor from meal count or fixture units. IS 5329 / NBC Part 9.
Grease TrapKitchenInterceptorIS 5329
Calculate
Design septic tank and soak pit for a building. IS 2470 / NBC Part 9.
SepticTankSoak PitIS 2470NBC
Calculate
Size roof drain outlets, gutters and downpipes from rainfall intensity. IS 1742 / NBC Part 9.
Roof DrainGutterDownpipeIS 1742NBC
Calculate
Total fire water storage requirement for combined hydrant + sprinkler demand. NBC Part 4 / IS 15105.
Fire TankStorageHydrantSprinklerNBC Part 4
Calculate
🚪
FIRE
Egress Width & Stair Sizing Calculator
Calculate exit door and staircase width from occupant load. NBC Part 4 / NFPA 101.
EgressExitStairNBC Part 4NFPA 101
💨
FIRE
Stairwell Pressurisation Calculator
Calculate pressurisation air quantity for smoke-free stairwells. NBC Part 4 / NFPA 92.
PressurisationStairwellSmokeNBC Part 4NFPA 92
Size LPG cylinder bank for commercial / industrial applications. IS 8884 / IGC.
LPGCylinderBankIS 8884IGC
Calculate
🔵
GAS
PNG / CNG Pipe Sizing Calculator
Size piped natural gas distribution network. PNGRB / IS 6044.
PNGCNGNatural GasPNGRBIS 6044
Size steam distribution pipes from load and pressure. IS 4503 / ASME B31.1.
SteamPipeASMEIS 4503
Calculate
Calculate Net Positive Suction Head available (NPSHa) to prevent pump cavitation. IS 9137 / HI.
NPSHSuctionCavitationPumpIS 9137
Calculate
MECH
DG Fuel Tank Sizing Calculator
Size diesel fuel tank for generator based on run-hours. IS 10000 / NBC.
DieselFuel TankGeneratorDGIS 10000
Maximum support span for loaded cable tray. IS 9537 / NEMA VE-1.
Cable TraySupportSpanIS 9537NEMA
Calculate
🔩
MECH
Pipe Support Span & Hanger Load Calculator
Maximum pipe support span and hanger reaction load. IS 1239 / MSS SP-69.
Pipe SupportHangerSpanIS 1239MSS SP-69
Refrigeration load for cold stores and chilled rooms. ASHRAE Refrigeration Handbook.
Cold RoomRefrigerationASHRAECooling Load
Calculate
Steam or water humidification capacity for AHU/space. ASHRAE 62.1.
HumidifierSteamHumidityASHRAE
Calculate
📊
HVAC
Room Sensible Heat Ratio Calculator
Calculate room SHR and verify AHU coil selection. ASHRAE Fundamentals.
SHRSensible HeatLatentASHRAE
Sensible and latent energy recovered by HRW. ASHRAE 90.1.
ERWHeat RecoveryASHRAE 90.1Energy
Calculate
HVAC
HVAC Energy - EER/COP/IPLV Calculator
Calculate EER, COP, IPLV and annual energy for chillers and AC units. ASHRAE 90.1 / BEE.
EERCOPIPLVChillerEnergyBEE
AHU cooling coil rows, face area and water flow. ASHRAE / AHRI.
Cooling CoilAHURowsAHRIASHRAE
Calculate
Size medium and high voltage cables for 11kV and 33kV systems. IS 7098 / IEC 60502.
HV Cable11kV33kVIS 7098IEC 60502
Calculate
Size copper or aluminium busbars for LV and MV switchboards. IS 8084 / IEC 60439.
BusbarIS 8084SwitchboardLVIEC 60439
Calculate
Estimate arc flash incident energy and PPE category. IEEE 1584.
Arc FlashIEEE 1584PPEIncident EnergySafety
Calculate
Size lead-acid or Li-ion battery bank for DC systems. IS 16242 / IEEE 485.
BatteryDC UPSIEEE 485IS 16242Autonomy
Calculate
Estimate total harmonic distortion from non-linear loads. IEEE 519.
THDHarmonicsIEEE 519Power Quality
Calculate
Check phase current balance and neutral current for a 3-phase LV system. IS 732.
Load BalanceNeutral3-PhaseIS 732
Calculate
Size domestic hot water storage heater or boiler. IS 2082 / NBC Part 9.
Hot WaterGeyserHeaterIS 2082NBC
Calculate
Calculate pressure surge from sudden valve closure (water hammer). AWWA / IS 2373.
Water HammerSurgePressureIS 2373AWWA
Calculate
Size sump pit volume and submersible pump for basement drainage. NBC Part 9.
Sump PumpEjectorBasementNBC Part 9
Calculate
💦
FIRE
Sprinkler Head Spacing Calculator
Maximum sprinkler head spacing and coverage area per hazard class. NFPA 13 / IS 15105.
SprinklerSpacingNFPA 13IS 15105
🔥
FIRE
Fire Load Density Calculator
Calculate fire load density and occupancy risk class. NBC Part 4 / ISO 1716.
Fire LoadOccupancyNBC Part 4ISO 1716
🔵
GAS
Gas Pressure Regulator Selection Calculator
Select gas pressure regulator from flow demand and pressure conditions. IS 6044 / IGC.
Gas RegulatorPressureIS 6044IGC
💨
GAS
Gas Room Ventilation Calculator
Ventilation air for gas meter rooms and boiler rooms to prevent accumulation. IS 6044 / NBC.
Gas RoomVentilationCombustion AirIS 6044NBC
Predict pump performance at new speed or impeller size. Hydraulic Institute / IS 9137.
Affinity LawsPump SpeedVFDIS 9137
Calculate
Select steam trap type and size from condensate load. IS 5290 / ASME.
Steam TrapCondensateIS 5290ASME
Calculate
〰️
MECH
Vibration Isolation Calculator
Select isolator type and static deflection for rotating equipment. ASHRAE / IS 2974.
VibrationIsolatorAnti-VibrationIS 2974ASHRAE
🏗️
MECH
Slab / Equipment Floor Load Calculator
Check slab load capacity for mechanical equipment. IS 875 Part 2 / NBC.
Slab LoadEquipmentIS 875StructuralNBC
🧱
MECH
Equipment Inertia Base (Concrete Pad) Calculator
Size concrete inertia pad for rotating equipment. IS 2974 / ACI 351.
Inertia BaseConcrete PadIS 2974ACI 351
⛏️
MECH
Pipe / Cable Burial Depth Calculator
Minimum burial depth for underground pipes and cables. IS 5822 / NBC / IE Rules.
Burial DepthUndergroundTrenchIS 5822NBC
🏢
MECH
Roof Load for AHU / Cooling Tower Calculator
Check roof structural load for rooftop HVAC equipment. IS 875 / NBC Part 6.
Roof LoadAHUCooling TowerIS 875NBC
Size AHU/FCU condensate drain pipe and slope from cooling capacity. ASHRAE / IMC 307.
CondensateDrainASHRAEIMCAHU
Calculate
P-trap seal and total depth for AHU drain pans from fan static pressure. Draw-through / blow-through.
CondensateP-TrapAHUStatic PressureASHRAE
Calculate
Size dust extraction ducts to minimum transport velocity so material stays airborne. ACGIH.
Dust CollectionTransport VelocityACGIHDuctExtraction
Calculate
Data centre / server room cooling load and airflow from rack power. ASHRAE TC 9.9.
Server RackData CentreHeat LoadASHRAE TC 9.9CRAC
Calculate
Size a diaphragm/bladder expansion tank for a closed hydronic (heating/chilled) loop.
ASHRAEHydronicClosed Loop
Calculate
Size a supply diffuser or return grille neck from airflow and target face velocity, with a noise check.
Air DistributionNCFace Velocity
Calculate
Estimate traction lift motor power and full-load current from rated load, speed and counterweight balance.
Traction LiftMotorFLC
Calculate
Circulation flow and filter area for a swimming pool from volume and required turnover time.
TurnoverFiltrationPool
Calculate
Commercial kitchen hood exhaust and make-up air from hood length, duty and style (IMC / NFPA 96).
NFPA 96ExhaustMake-up Air
Calculate
Collector area and tank size for a solar thermal hot-water system from daily demand.
Solar ThermalCollectorHot Water
Calculate
Rolling-sphere protection radius and down-conductor count for an LPS (IS/IEC 62305).
IEC 62305Rolling SphereLPS
Calculate
AD - Google AdSense Placeholder
📐 Formula Library
80 MEP engineering formulas - searchable, with derivations, examples and IS code references
🔏 Digital Stamp Generator
Create a professional engineer stamp for your PDF reports and drawings
Engineer Details
Stamp Style
Round
Rectangle
Hexagonal
Stamp Color
Live Preview
My Saved Stamps